temtron inc globe   Worldwide Shipping
sales Sales
Qualified and knowlegable sales people. Large Inventory. Quick delivery.
service Service
Industrial electronic repair service, Quick turn-around. Best price and warranty in the industry.
support Support
Need a product catalog? Quote? Application engineering help?
 
 
DME HOT RUNNER TEMPERATURE CONTROL REPAIR SERVICE
request for quote repair service
Temtron specializes in DME hot runner repair. We can repair all of your controls, mainframes, and cables. Standard repair pricing is available on DME controllers. We offer a low price guarantee. All DME hot runner repair and calibration tasks are performed in-house with equipment traceable to the National Institute of Standards and Technology. 






DME HOT RUNNER 
dme hot runner repair fc10d
dme hot runner repair fc10a
dme hot runner repair dss15g
dme hot runner repair ssm15g
dme hot runner repair css15g
dme hot runner repair fc100g
dme hot runner repair smp10g
dme hot runner repair ssm1502
FC10D
FC10A
DSS15G
SSM15G
CSS15G
FC100G
SMP10G
SSM1502

 
Repair Service of these DME Hot Runner system model numbers
 
DME Control Model Numbers
Mainframes
Control Board
 
062U
DSS-15 FC15
FCX10S
PMR15
SSH-10-02
MFHP2G
SSM15G1
  CMP10G DSS-15-02
FC15A
FCX10DSG
PSS15
SSM15G
MFHP3G
 
 
CMP10
DSS-15-G
FC15AG
MFPR-2G
SBH10
SSM15
MFHP5G
Pyrometer
 
CMP15
FC10
FC15DG
PC-2
SMP10
SSM30
MFP-12G-W/O
TS200
 
CMP15E
FC10A
FC30
PCP-1M
SMP10E
SSMX15G
 
 
 
CMP15G
FC10AG
FC30AS
PEC-50S
SMP10G
 
Heat Module
 
 
CMP30
FC10AS
FC5
PEC-5ES-2
SMP15
 
PSS15G
 
 
CMP10G
FC10ASG
FC679A10
PFC5
SMP15E
 
 
 
 
CSS15G
C10DS
FCS-15
PFC5AS2
SMP15G
 
 
 
 
CSS-15-02
FC10DSG
FCS-10
PMR10
SMP30
     

SPECIAL AND CUSTOM CABLES AVAILABLE
dme hot runner cable repair

Temtron can build most special or custom cables to fit most needs. Example: Run molds equipped for INCOE using a DME Hot Runner control system or the reverse. Tell us what YOU need!

DME Hot Runner Cable Repair
 
New DME hot runner power and thermocouple cables can be very costly. Let Temtron repair your defective DME hot runner cables at a significant savings.

DME Hot Runner Control Repair - Advanced Techniques Used
DME Controls are Provided with a Unique Serial Number
dme repair board before
Temtron understands that when your DME temperature control no longer operates properly or becomes damaged, you would like it repaired quickly and at a reasonable price. Over the years we have developed some repair and calibration techniques that allow us to economically repair almost all DME temperature control modules that we receive.
dme repair board after
One example of this is our foil replacement process. Temtron has developed a process of replacing damaged printed circuit board edge connector foils during DME control repair as shown in the Before and After pictures. This allows us to perform DME control repair on units with extensive damage on the printed circuit board for like-new performance.
dme repair serial number

o

After the repair process has been completed, the number provides warranty data.

o

Ensures that the controller you sent us is the exact one we return to you.

o

Allows in-house tracking of work in progress during the repair process for faster turn around.

o

During repair, the number determines what component and hardware updates have been performed, so your control is as current as possible.

 
Temperature Control Modules: How to prevent damage
(1)

Control module fuses must be rated at 250 VAC, type F (fast blow). This will protect the module in the event of a shorted heater. Fuse current rating should match the module size - usually 15 or 30 amp.

(2)

The power switch should be in the "off' position before you install or remove the module from an energized mainframe (mf switch "on"). This will prevent edge foil damage.

(3)

The fuse holder should grip the fuse ends tightly to maintain good contact. Pinch the fuse holder clips together some if the fuse is loose in the holder. Be aware of soft, easy to bend clips, as they probably will not maintain good fuse contact. Poor fuse contact can produce small electrical arcs causing pitting and oxidation, and will eventually cause premature fuse blowing.

o RMA Number not required
o We ship open account on approved credit
o All major credit cards accepted
temtron packaging suggestions

payment options
©2010 Temtron, Inc. All Rights Reserved